DEWTRON ™
Digital multi-channel temperature and dew-point sensor
Measuring field: Umidità Relativa 0-100%; Temperature -40°…+120° C
Reply time: > 4 sec
Protection: IP67
Power supply: 10/36V dc 8/26V ac
Digital output: programmable RS232, RS485
Output with relay: two programmable thresholds

- Measuring field
-
- U.R.:0% -100%
- TEMP:-40°- +120° C
- Resolution
-
- Accuracy
-
- +/- 2%RH RH in range of 10% and 90%RH
- +/- 0,4°C in range of 5 and 40°C
- +/- 1°C in range of -20°C/70°C.
- Repeatability
-
- Reply time
- >4 sec.
- Operating temperature
-
- Sensor:-40 / +120 °C
- Trasmettiter:0° / +70°C
- Box protection
- IP 67
- Electrical connections
- Internal terminal board accessible through water tight cable guiding-slit
- Cable length
- Transmitter-sensor cable: 1.0 m, 2.0m
- Power supply
- 10/36V dc 8/26V ac
- Dissipation
- Max. 1,5W
- Protection
- microfuse 2A
- Outputs
-
- Serial RS232
- Programmable baud rate: 1200, 4800, 9600, 19200 baud
- Serial 485
- Configurability with 4 bit address
- Baud rate configurability
- Digital alarm output: relay 2A / 120V
- Two settable release thresholds
- Hysterisis realized to avoid output fluctations
- User interface
-
Possibility to set:
- communication baud rate
- measuring frequency
- alarm release threshold
Possible reading of:
- set parameter state
- temperature / humidity measurements
- alarm release thresholds
- Material
-
-
Sensor body: shaft made of stainless steel 316L
- Sensor protection made of plastic ABS or bronze
- Transmitter box: polycarbonate
- Dimensions
- Sensor:
Threaded M12x1 Length 70 mm (threaded body) + 40 mm (filter)
- Transmitter box: 120 mm x 80 mm x 56 mm
- Layout internal terminal board
-
- 1,2: POWER IN: 10/34Vdc, 8/26Vac.
- 3: EARTH
- 4: ALARM: Normally Closed.
- 5: ALARM: Nornally Open
- 6: ALARM: COMMON
- 7: GND serial 485 (fuse protected 100mA)
- 8: + serial 485 (fuse protected: 100mA)
- 9: - serial 485 (fuse protected: 100mA)
- 10: GND serial 232
- 11: RX serial 232
- 12: TX serial 232